Question: 1
A customer has an HP ProLiant DL380 Gen9 server with one processor that has a large RAID 5 SAS Array configured on a P440ar storage controller with a hot spare. During the rebuild process, a second SAS drive failed.
What should the integrator do to help prevent this problem from reoccurring?
A. Configure a higher Rebuild.
B. Priority Install a second hot spare disk drive.
C. Install more memory in the server.
D. Use the integrated B140i controller.
Answer: D
Question: 2
A system integrator installed an operating system on an HP ProLiant Gen9 Server.
Which operating system can be used with UEFI Boot Mode?
A. VMware ESXi 5.5
B. Windows Server 2008 32-bit
C. Citrix XenServer 6.0
D. Windows Server 2003 64-bit
Answer: A
Question: 3
A customer with ProLiant Gen9 based servers needs to add external storage to some of the servers.
Which component should the integrator recommend?
A. 12GB SAS Expander Card
B. HP Smart Array P841
C. HP Smart Array P440ar
D. HP IO Accelerator
Answer: ...
... C
Question: 4
What is a benefit of using 20Gb FlexFabric Converged network adapter (CNA) for the BladeSystems?
A. It allows support tor RDMA over Converged Ethernet (RCOE) when the HP 6125XLG is used in conjunction with the FlexFabric adapter.
B. It delivers 10Gb performance per port with an aggregate 20Gb in a dual-port adapter.
C. The adapter streams converge 10GbE and 16Gb storage simultaneously over the same 20GD port.
D. Performance is delivered through multiple 2/10Gb ports using multiple adapters in a teamed fashion.
Answer: A
Question: 5
An integrator is installing an HP ProLiant DL380 Gen9 server with an H240ar controller installed. The integrator needs to install a total of 24 SFF Drives.
Which additional task must the integrator perform to meet the requirements?
A. Add an HP 12 GB SAS Expander Card cabled to the H240ar and cabled to two SFF backplanes.
B. Ada an SFF cable and an SFF backplane to the H240ar.
C. Add two more H240ar controllers with 8 SFF drives attached to each controller.
D. Add a rear drive cage backplane and cable it to the M240ar.
Answer: C
Add Comment
Education Articles
1. Tested Tutor Reading Comprehension In Wellington: Enhancing Literacy Skills For Lifelong LearningAuthor: khizar haider
2. Studyauracle
Author: Studyauracle
3. 10 Digital Marketing Tools You Must Use In 2025
Author: neetu
4. School Tutor Website In Palm Beach
Author: khizar haider
5. Studying Mbbs Abroad Is A Way To Successful Mbbs Career
Author: Mbbs Blog
6. Join Microsoft Dynamics 365 Courses – Online Training
Author: Pravin
7. Gcp Cloud Data Engineer Training | India
Author: naveen
8. Generative Ai For Devops Training Classes | Visualpath
Author: Visualpath
9. Best Az-305 | Azure Solutions Architect Expert Training
Author: gollakalyan
10. Tomorrow Starts With A Healthy Today
Author: Akshaya Patra
11. Gen Ai Training In Hyderabad | Best Generative Ai Training
Author: Susheel
12. Top Sap Ariba Training Institutes | Sap Ariba Training In Bangalore
Author: krishna
13. Safety & Health At Work - Qqi Level 5 Qualification
Author: johnnytorrt
14. School Tutor Website In Boynton Beach
Author: khizar haider
15. How To Become A Special Needs Tutor In Jacksonville
Author: khizar haider