ALL >> Environment >> View Article
Fieldsense Rf Personal Monitors Verified By Acrbr
The ProHD® fieldSENSE personal RF monitor was recently put through rigorous validation testing. This work was carried out by the noted Australian Centre for Bioeffects Research (ACRBR) at Swinburne University of Technology in Hawthorn, Melbourne, Australia.
ACRBR independently tested the fieldSENSE monitor operation for continuous wave (CW) exposure and also for signals representative of real signals found at typical mobile base station transmitter sites.
Two sample fieldSENSE monitors (one occupational, one public) were provided by EMSS for calibration. The fieldSENSE monitors are stand-alone, battery powered, handheld devices designed for use by technical personnel working in the vicinity of mobile base station antennas. They give the user an indication of the radiofrequency (RF) electric (E) field exposure level relative to either the occupational or public reference levels prescribed by exposure limits in a nominated standard. The sample units provided for this calibration were designed to indicate relative exposure to the 1998 EMF exposure guidelines issued by the International Commission for Non-Ionising ...
... Radiation Protection (ICNIRP).
fieldSENSE Monitor Under Test
This calibration set out to assess whether the sample fieldSENSE devices that were provided perform within the manufacturer's uncertainty specifications, with due regard to the uncertainty of the ACRBR calibration procedure. The manufacturer EMSS has calculated the uncertainty in the E-field response of the fieldSENSE devices to be +3.3 / -3.6 dB over the full frequency range of operation.
The fieldSENSE monitors were calibrated for all seven LED response levels at 900 MHz and 1800 MHz (CW), and for the highest three of the seven LED response levels for GSM and DMA modulated signals. The tests were conducted by Dr. Vitas Anderson and Ray McKenzie.
The tests found that performance of the ProHD® fieldSENSE RF monitors was well within the manufacturer specification for all tested modalities.
For CW exposures at 900 and 1800 MHz, and in the configuration tested, the average error across all LED levels in E-field response of the sample occupational and public fieldSENSE monitors ranged from – 1.29 dB to +2.09 dB. This is well within the factory expanded uncertainty specifications of +3.3 / -3.6 dB. Compared to CW exposures, the fieldSENSE monitors responded differently to the digital modulated signals of GSM and WCDMA mobile network signals by up to 0.85 dB. However, these differences still place the fieldSENSE monitors well within the factory expanded uncertainty specifications of +3.3 / -3.6 dB.
Download the full testing report here. More about the fieldSENSE ProHD® monitor and your purchase connection is at http://www.lbagroup.com/technology/fieldsense-personal-rf-monitor.php.
LBA Group, Inc. has over 50 years of experience in providing worldwide RF asset solutions and electromagnetic energy risk management for industrial and telecommunications infrastructure. The group is comprised of LBA Technology, a leading manufacturer, distributor and integrator of radio frequency systems, lightning protection, and EMC equipment for broadcast, industrial, and government users; the professional technology consultancy Lawrence Behr Associates, and LBA University, providing on-site and online professional training. LBA has been recognized as an Inc5000 growth business, a Top50 diversity business in North Carolina and is a CMSDC certified Hispanic small business. The companies are based in Greenville, N.C., USA. Visit their homepage.
Add Comment
Environment Articles
1. Pest Control Services In Trichy | Keep Your Home & Office Pest FreeAuthor: Massclick
2. Power Weeder Machine
Author: mechnova
3. The Exposed-ground Gap: Protecting Prepared Soil Between Earthworks And The Next Stage Of Construction
Author: Ray Cooper
4. The Reliable And Unrivaled Remedial Action Plan Nsw
Author: Sydney Environmental Group Pty Ltd
5. The Ground Beneath Oilfield Logistics: How Access-road Reliability Influences Equipment Mobilization And Site Readiness
Author: Clay Anderson
6. Rethinking Gravel Road Maintenance Cycles: Integrating Dust Suppression Into Preventive Maintenance Planning
Author: Ray Cooper
7. The Application Window: Why Preparation, Moisture, And Application Conditions Matter In Polymer-based Dust Suppression
Author: Clay Anderson
8. Climate Adaptation: Building A Resilient Future In A Changing World
Author: Manjeet Singh
9. 7 Plan-set Red Flags That Get Commercial Solar Permits Rejected
Author: Jerry Ken
10. How To Read Your Synergy Bill After Going Solar
Author: Fusion Sun
11. Where To Watch Saanvi Movie Stream Saanvi Now On Dynoxe
Author: Arun Konda
12. Why Bamboo Toothbrushes Are Better For The Planet
Author: ema
13. How Can A Phase 1 Contamination Report Help Sydney Property Owners?
Author: Sydney Environmental Group Pty Ltd
14. The Voice From The Well – कुएँ से आने वाली आवाज़
Author: Divant Sharma
15. Transforming Business Energy With Commercial Solar
Author: 3P solar






