123ArticleOnline Logo
Welcome to 123ArticleOnline.com!
ALL >> Business >> View Article

Standard Cleaning Process For Measuring Instruments

Profile Picture
By Author: Calibration Laboratory
Total Articles: 2
Comment this article
Facebook ShareTwitter ShareGoogle+ ShareTwitter Share

The standard cleaning process begins with the design of the measuring instrument that needs to be calibrated. The design has to be able to “hold a calibration” through its calibration interval. In other words, the design has to be capable of measurements that are “within engineering tolerance” when used within the stated environmental conditions over some reasonable period of time. Having a design with these characteristics increases the likelihood of the actual measuring instruments performing as expected.Cleaning of Pressure GaugeReceive the pressure gauge and clean the pressure gauge (To make it free form the chemical contamination) as per the steps mentioned below. First of all clean the outer surface of the pressure gauge with cotton waste to remove dirt / dust etc. Take Tri-Chloro Ethylene bottle and such Tri-Chloro Ethylene in the 200 ml. injection. Fill the injection completely with Tri-Chloro Ethylene. Inject thee TCE in the pressure gauge to clean the inside part of the pressure gauge. Repeat the above mentioned steps till approx, clean Tri-Chloro Ethylene comes out after injection to ensure ...
... that pressure gauge is cleaned from inner side completely. Cleaning of Glassware Remove obviously loose contamination mechanically from the glassware by bruising, shaking with water (if necessary, containing pieces of filter paper). Remove all or grease by suitable solvents. Neatly fill the glassware with an aqueous solution of a sapless detergent, and shake vigorously. Rinse preparedly with tap water until trace of the detergents removed. Finally rinse with distilled or deionizer water. Verify that the walls of the glassware are clean. If the wall are not satisfactorily clean after the above treatment fill the glassware with the mixture of equal parts by volume of saturated solution of potassium dichromate and concentrated Sulphuric acid, and allow to stand for 1 hour. Take care that the acid does not come in contact with the outside of glassware, unless it is known that the filling of the graduation marks is resistant to it. Rinses the glassware again with tap water until traces of acid are removed. Finally rinse with distilled or demonized water and again verify that the walls are clean: if they are not, repeat the procedure. After cleaning, rinse the glassware, adjust to contain, with ethyl Alcohol and dry with clean air at room temperature. Alternatively, if the glassware is not required for immediate use, it may be kept filled with distilled or demonized water. It is not necessary to dry a glassware marked or deionizer water. It is not necessary to dry glassware marked ‘To Deliver’.

ISO 17025 laboratory consultant written articles concerning ISO 17025 certification, and additionally creates content with what is calibration, Cleaning Process, calibration process, instruments calibration and more. I have also offers calibration laboratory services, area associates franchisee services offering in India.

Total Views: 201Word Count: 462See All articles From Author

Add Comment

Business Articles

1. Lucintel Forecasts The Global Wall-mounted Ac Ev Charger Market To Grow With A Cagr Of 22.4% From 2025 To 2031
Author: Lucintel LLC

2. Technology Landscape, Trends And Opportunities In Global 3d Printing Photopolymer Market
Author: Lucintel LLC

3. Lucintel Forecasts The Global Smart Home Market To Reach $372 Billion By 2030
Author: Lucintel LLC

4. Second Marriage Matrimonial – Verified Matches & Free Registration
Author: Truelymarry

5. Core: Leading The Way In Managed It Services For Businesses Across London
Author: IT Management

6. The Role And Function Of A Collection Agency
Author: Bennett Carter

7. Understanding Debt Collection Agencies: What They Do And How They Affect Consumers
Author: Bennett Carter

8. How To Use An Smm Panel Effectively For Fast Social Media Growth
Author: Smm Panel

9. Essential Tips For Beginners And The Power Of Professional Editing
Author: Sam

10. How To Improve Field Staff Efficiency With Geolocation Tools
Author: TrackHr App

11. Building An Effective Energy Management System
Author: Jane

12. Internal Auditor Training: The Key To Effective Risk Management And Compliance
Author: Sqccertification

13. Why Accurate Accounting In Property Management Is The Key To Higher Roi
Author: Harsh Vardhan

14. Kaal Sarp Puja In Trimbakeshwar – Benefits, Process & Trusted Pandit Contact
Author: Pandit Milind Guruji

15. Data Entry Vs. Data Processing: What’s The Difference And Why It Matters
Author: Allianze BPO

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: