Industry areas such as chemical, pharmaceutical, and various industrial processes have explosive environments that require the equipment to be specially constructed to minimize the risk of gas or dust ignition. Fans are one of the items of industrial equipment that have potential to ignite either gas or dust from either sparks caused by contact of the fan wheel and housing, or because of fan motors with high temperatures, inadequate gas/dust ingress protection, or inadequate construction for prevent spark or flame propagation in to the surrounding atmosphere.

The likelihood of sparks with the fan housing is minimized through use of special types of spark resistant construction, depending on the type of protection required.

AMCA “A” spark resistant construction: Highest degree of spark resistance. Airstream parts are constructed out of non-ferrous materials. Typically, aluminum is the non-ferrous material used, but for certain applications, such as high temp, where aluminum cannot be used, CB Blower has the capability to use alternative materials including Monel®, Inconel®, and Hastelloy®.

AMCA “B” ...
... spark resistant construction: Less protection that AMCA “A” construction, AMCA “B” construction consists of a non-ferrous wheel and non -ferrous rubbing plate around the hole through which the shaft passes. As with AMCA “A” construction, aluminum in usually the non-ferrous material of choice but can be substituted with the alternative materials listed for AMCA “A” construction.

AMCA “C” spark resistant construction: Lowest degree of spark resistance. Utilizes only a non-ferrous rubbing plate that is typically constructed of aluminum but can be constructed out of the aforementioned alternative materials when appropriate.

In addition to spark resistant construction, motor construction appropriate to the explosive environment must also be considered. UL explosion standards classify explosive environments according to Class, Group, and Division. The class indicates whether 1. Gases, vapors, liquids are present, 2. Dusts are present, 3. Or Fibers and flyings. The Group specifies what types of vapors, dusts, fibers, etc. are present. The Division specifies the frequency of the presence of the hazardous substances.

Class, Group, and Division are specified by the client, and CB Blower works closely with our motor manufactures to determine the best motor that conforms to those specifications. Many of our fans are appropriate for explosion proof environments, but due to the interdependence of many factors, each situation must be considered uniquely.

Emergency smoke exhaust systems are designed to remove smoke and heat from buildings in the event of a fire. These systems play a crucial role in increasing occupant safety and allowing rescue personnel to safely enter burning buildings. CB Blower offers a full line of smoke and heat fans capable of withstanding a minimum temperature of 500°F for four hours or 1,000°F for 15 minutes. Our inline smoke and heat fans are also available in a vertical roof mount configuration featuring a discharge cap with butterfly dampers and an optional fusible link designed to stay open in the event of a fire.

For additional information please refer to http://www.cbblower.com/coolair.html

Oleg Chechel
Ventilation Equipment Designer
olegsystems@olegsystems.com
CB Blower Co.
http://www.cbblower.com/custserv.html
http://www.cbblower.com/index.html

Total Views: 525Word Count: 491See All articles From Author

Add Comment

Business Articles

1. Why Choose Ac On Rent In Mumbai Instead Of Buying?
Author: Shoaib Shaikh

2. How Walkable Skylights Transform Flat Roofs Into Usable Spaces
Author: ADVAN

3. How Engineering Firms Can Match Workforce Capacity To Project Phases
Author: Bhargav

4. Rewriting The Rules Of Seo: Keep Your Brand In Front Of Customers
Author: Devakey Digital Solutions

5. Skilled Brunswick Workers Comp Lawyer Helps Protect Your Claim
Author: ADVAN

6. What Is A Payroll Clearing Account And How It Works
Author: ADVAN

7. Why High Temperature Thermocouple Sheath Selection Matters
Author: ADVAN

8. The Crucial Factors That Shape Every Room Heater Price Tag
Author: sundar

9. When Winter Comfort Calls For A Different Kind Of Heat
Author: sundar

10. Heat Exchanger Manufacturer In India: How To Choose The Right Partner For Your Plant
Author: Laxman Pachkawde

11. Reliable Well Servicing In Alberta With Synergy
Author: John Martin

12. Choosing Among The Best Well-servicing Companies In Alberta
Author: John Martin

13. Why Filter Maintenance Is Important For Industrial Vacuum Cleaners
Author: Steve Smith

14. Lucintel Forecasts The Global Batch Inclusion Eva Bag Market To Reach $3 Billion By 2035
Author: Lucintel LLC

15. What Should You Look For When Choosing House Painters In Adelaide?
Author: Viva Painters Adelaide

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: