Tenderall Fan Co. enginners truly reversible (exhaust and supply roof fan for general ventilating.

The Type CBRE recirculators are designed for use in commercial and industrial applications where there is sufiicient ceiling height to create a temperature differential between the floor and the ceiling. These applications include factories, warehouses and large commercial buildings.

CBRE Roof Recirculators function as regular power roof ventilators in warmer weather and as an energy-saving recirculation air system in cold weather. Each unit is equipped with a reversible fan that distributes warm ceiling air thoughout the plant and reduces the builing's heating requirements. With a flip of a switch it can function as a conventional roof ventilator. There are two unit types: 1) for exhaust and recirculation; 2) for exhaust, supply and recirculation.

Available fan wheel sizes are from 24" to 60", performances: up to 50,000 CFM @ 1/2" WG.

The reversible propeller incorporates specifically engineered airfoil sections and hub size for optimal efficiency and physical strength. Alternate adjustable pitch ...
... propeller blades are turned 180 degrees to one another and a double orifice is attached to the fan panel.

Type HS PRVs reliably extract large volumes of hot gases and smoke regardless of building configuration, location and weather conditions. They withstand high temperatures for long periods of time.

Another reliable ventilation system that can operate during a fire is Tenderall Fan Type HS Heat and Smoke Roof Ventilator. It prevents smoke logging, allows people to escape quickly, minimizes damages to property and contents and enables firemen to attack the fire without hindrance. These power roof ventilators have the added advantage of providing normal day to day ventilation and in many cases can also be fitted with duct work for use in multi storey buildings.

The concept of venting smoke and heat was first outlined by Industrial Risk Insurers (IRI). Use of powered ventilation could eliminate the problems experienced with gravity vents. Specially designed roof mounted exhaust fans would mechanically vent heat and smoke under emergency fire conditions.

The unique Type HS power roof ventilators provide a solution for emergency heat and smoke venting that is dependable under the most extreme circumstances.

All critical components of HS PTV that exposed to the airstream are ferrous construction to withstand high temperature conditions. These heavy gauge materials prevent warping of fan parts and malfunction at high temperatures. This also insures years of trouble-free service in normal daily operation of the PRV.

Belt and bearings are protected from the air stream by enclosing them in a ventilated tube. Design of HS fan incorporates a heat slinger/impeller. It isolates the fan bearings from damaging heat and draws cooler outside air through the motor compartment and over the belt and bearings. A spring loade, fusible link activated device automatically opens dampers when temperature at the fan reaches 165 F. Thei enables the fan to function as a gravity ventilator prior to powered operation.

Type HC Power Roof Ventilators have been tested to operate:

- conituously at 650 F;
- 3 Hours at 800 F;
- 1.5 Hours at 1000 F;
- 1/2 Hour at 1,200 F.

Additional information can be found at the Canada Blower company web site http://www.tenderall.com/ventilator/index.html.

Oleg Tchetchel
Industrial Process Designer
Tenderall Fan Co.
http://www.tenderall.com/contact/index.html
http://www.tenderall.com/index.html

Total Views: 311Word Count: 518See All articles From Author

Add Comment

General Articles

1. Neotonics: A Comprehensive Review Of The Skin And Gut Health Supplement
Author: Neotonics: A Comprehensive Review of the Skin and

2. Why Maintain Your Car Properly?
Author: Anthea Johnson

3. How Seva In Dharma Makes The World A Better Place
Author: Chaitanya Kumari

4. British And Irish Lions: Aunz V Lions Test Add On The Line
Author: eticketing.co

5. What Is Kpi And Kra? A Complete Guide To Performance Management Metrics
Author: TrackHr App

6. A Complete Guide To The Best Schools In Bhopal For Academic Excellence
Author: Ronit Sharma

7. British And Irish Lions 2025: Fans React To Shock Omissions
Author: eticketing.co

8. A Complete Guide To Installing Meter Boxes Safely And Correctly
Author: adlerconway

9. Your Shortcut To Smarter Learning
Author: coursefpx

10. Unencumber A Logo-new Way Of Life At Krisala 41 Commune Wakad: Wherein Luxurious Meets Clever Residing
Author: Armaan

11. Headless Wordpress As An Api For A Next.js Application
Author: brainbell10

12. Firebase And Crashlytics In Flutter And Swift
Author: brainbell10

13. Guide To Replacing And Maintaining Backhoe Loader Hydraulic Cylinders
Author: Seetech Parts

14. What Is The Difference Between On-grid, Off-grid, And Hybrid Solar Systems?
Author: Vishtik

15. Mobile Internet Usage Growth In Usa
Author: Jenny Knight

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: