A residual chlorine analyzer or meter has various applications including:

• Continuous chlorine monitoring
• Water treatment plant residual chlorine control
• Secondary chlorination free chlorine control
• Distribution monitoring for total residual chlorine
• Cooling tower chlorine monitoring and control
• Pasteuriser chlorine dosing control
• Seawater chlorination control
• Chlorine in seawater monitor

The membraned amperometric chlorine sensor is enhanced with a third, reference, electrode which eliminates zero drift. pH correction is often not required at all. (NB. These chlorine sensors are often known as polarographic chlorine sensors although this is a misuse of the word polarographic).

The chlorine sensor used by the Residual Total Chlorine Monitors and the Residual Free Chlorine Monitors are both largely pH independent meaning that both chlorine analyzers are bufferless and reagentless. They both utilize amperometric chlorine sensors and both show remarkable sensitivity and stability. For those making a chlorine measurement at high pH (>pH ...
... 8.5) on variable pH water it is possible to provide pH compensation from either a pH sensor connected to the chlorine analyser or from an external pH meter.

The chlorine sensors work by separating the electrodes that perform the chlorine measurement from the sample, by a membrane. This membrane allows the free residual chlorine (HOCl and OCl-) or the Total Residual Chlorine (HOCl and OCl- plus chloramines) through the membrane. Inside the sensor the residual chlorine meets the electrolyte which is at a low pH. This converts the majority of the OCl- to HOCl. The HOCl is reduced at the gold working electrode and the current generated is proportional to the Free Chlorine or Total Chlorine present, and the chlorine analyzer gives a reading in chlorine ppm or mg/l.

This technique is the most advanced method of continuous chlorine measurement and has many benefits to the user including a very stable chlorine measurement and better chlorine dosing control.

In addition to residual chlorine measurement the free chlorine sensor determines the chlorine concentration and the chlorine analyzer can control the chlorine dosing using a variety of control algorithms including PID control.

The Residual Chlorine Monitor is bufferless and reagent free, meaning it has a low total cost of ownership and with maintenance intervals at 3 or even 6 months, the HaloSense bufferless Chlorine Monitor is fast becoming the instrument of choice for the engineer who wants the best chlorine monitor at the best price.

The HaloSense Free and Total Residual Chlorine Analyzers are equipped with process control options, datalogging, relay outputs, serial comms, (TCP, Ethernet, ModBus are available now with Profibus available soon). Remote Access of the chlorine monitors (including remote access to all control options) is available via the internet, and via a LAN. In fact the HaloSense range of chlorine analyzers has all the options you could want in a chlorine analyzer whilst maintaining a low cost and great value for money.

Total Views: 682Word Count: 453See All articles From Author

Add Comment

Environment Articles

1. The Exposed-ground Gap: Protecting Prepared Soil Between Earthworks And The Next Stage Of Construction
Author: Ray Cooper

2. The Reliable And Unrivaled Remedial Action Plan Nsw
Author: Sydney Environmental Group Pty Ltd

3. The Ground Beneath Oilfield Logistics: How Access-road Reliability Influences Equipment Mobilization And Site Readiness
Author: Clay Anderson

4. Rethinking Gravel Road Maintenance Cycles: Integrating Dust Suppression Into Preventive Maintenance Planning
Author: Ray Cooper

5. The Application Window: Why Preparation, Moisture, And Application Conditions Matter In Polymer-based Dust Suppression
Author: Clay Anderson

6. Climate Adaptation: Building A Resilient Future In A Changing World
Author: Manjeet Singh

7. 7 Plan-set Red Flags That Get Commercial Solar Permits Rejected
Author: Jerry Ken

8. How To Read Your Synergy Bill After Going Solar
Author: Fusion Sun

9. Where To Watch Saanvi Movie Stream Saanvi Now On Dynoxe
Author: Arun Konda

10. Why Bamboo Toothbrushes Are Better For The Planet
Author: ema

11. How Can A Phase 1 Contamination Report Help Sydney Property Owners?
Author: Sydney Environmental Group Pty Ltd

12. The Voice From The Well – कुएँ से आने वाली आवाज़
Author: Divant Sharma

13. Transforming Business Energy With Commercial Solar
Author: 3P solar

14. Vic Solar Rebate: What Victorian Homeowners Need To Know
Author: thesolarking

15. How Many Solar Photovoltaic Panels Do I Need For My Home In Ireland?
Author: Solar Panels Ireland

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: