What Is A Fuse ? And How To Test It
A fuse is a very thin wire, which either melts or vaporizes when too much current flows through it. The thin wire may be made of aluminum, tin-coated copper or nickel. The resulting open in the circuit stops current flow. In electronic equipment, most fuses are cylindrical glass or ceramic type with a metal cap at each end! The current rating also can be seen in one of the two metal end caps. There are two popular physical sizes: 1 - ¼ X ¼ - inch and 5X20mm. The 1 - ¼ X ¼ - inch size is used in many automobiles. You'll find both sizes in many electronic equipment, but the smaller 5 X 20mm has become more common. Fuses are available with current ratings from 1/500 Ampere to hundreds of amperes.
Purpose of Fuses
The purpose of a fuse is to open an electronic circuit when current flow exceeds a certain amount, determined by the rating of the fuse. Opening a circuit under high current conditions can save electronic components from damaged and prevents overheating, which could cause a fire.
Types of Fuses
There is two basic types of fuses: fast acting and slow blow. The fast ...
... acting type will open very quickly when their particular current rating is exceeded. This is important for analog meter movements, which can quickly be destroyed when too much current flows through them, for even a very small amount of time. Slow blow fuse have a coiled construction inside. They are designed to open only on a continued overload, such as a short circuit. The purpose of coiled construction is to prevent the fuse from blowing on just a temporary current surge.
Do not use a slow blow fuse in place of a fast acting fuse. It may not open fast enough to prevent components damage under a high current condition. It's not harmful to replace a slow blow fuse with a fast-acting fuse, but it will probably open up unnecessarily every now and then when the equipment is first switch on. A blown fuse can tell you something about your service problem. Often the glass case of the fuse appears clear, and you can still see the broken pieces of the fuse element. This means you have the kind of problem that causes a slow, gradual overload on the power supply. Some fuses even die of old age. But if the inside of the glass fuse is discolored, and there is no trace of the fuse element (the center connector), you know that the center connector was destroyed quickly and violently, using a lot of heat. The fault was a short circuit or other problem that caused a lot of current to flow very quickly.
Is some cases a fuse will open up fast enough when there is a surge so that other components aren't damaged. If this is the case, replacing the fuse with one of the same type and rating restores operation. Unfortunately, a high probability exists that if a fuse blew, something in the circuit it was protecting shorted out. In this case, a replacement fuse blows right away. The blown fuse can easily be replaced by a new one, after the overload has been eliminated when come into replacement. Use only the same current and voltage ratings as the original. The common type and current rating of a fuse in a monitor are slow blow 2A to 5A. When you buy replacement fuses, get several - you can easily use all of them while you're troubleshooting an elusive problem.
Testing Fuses
Turn the power off and remove the fuse from the circuit to check with a multimeter set to the lowest ohms range. Connect the probes to both end of the fuse. You may check the fuse while it still in circuit. A good fuse should showed continuity or read 0 ohm. A blown fuse is open which reads infinity on the meter.
About the Author
Jestine Yong is a electronic repairer and a writer. For more repair information, please visit http://www.noahtec.com
Add Comment
Technology, Gadget and Science Articles
1. The Economics Of Final-stage Package Delivery: A Comprehensive Market OverviewAuthor: Shreya
2. Growth Outlook Of The South Korea Cytogenetics Market: Clinical Applications And Technological Innovations
Author: Shreya
3. U.s. Water And Wastewater Treatment Technologies Market 2025–2035: Growth Trends And Future Opportunities
Author: Shreya
4. Instashop Egypt Real-time Api - Sku-level Stock & Availability Mapping
Author: Actowiz Solutions
5. Web Scraping Canadian Grocery Retailer Pricing Data
Author: REAL DATA API
6. Why Erp Is Critical For Manufacturing Innovation
Author: Focus Softnet
7. Umbraco Vs Wordpress: Choosing The Right Cms For Your Business
Author: Addact Technologies
8. How Web Development Enables Seamless Integration With Third-party Tools And Apis
Author: jessika
9. E-commerce Growth By Jumia Data Scraping For Market Research
Author: Web Data Crawler
10. Web Scraping Api For Minibar Delivery Liquor Data In Usa
Author: Food Data Scraper
11. Web Scraping Hulu Ratings And Engagement Data
Author: REAL DATA API
12. Christmas Liquor Demand Data Scraper
Author: Actowiz Solutions
13. Best Buy Product Price & Item Data Scraping Guide
Author: Retail Scrape
14. Top 100 Christmas Gifts 2025 Data Analytics
Author: Actowiz Metrics
15. Scrape Ezpawn Store Locations To Map Pawn Industry Trends
Author: REAL DATA API