Adjustment Method Of Expansion Valve Of Air-cooled Box Chiller

Profile Picture
By Author: monica
Total Articles: 10
Comment this article
Facebook ShareTwitter ShareGoogle+ ShareTwitter Share

When the expansion valve is adjusted, it is necessary to rely on the adjustment rod to adjust the pressure of the spring, wherein the adjustment rod is turned inward to compress the spring, and turned outward to relax the spring. Rotate clockwise, the adjustment rod will be screwed in, otherwise, it will be screwed out.

During the operation of the refrigeration system, the adjustment direction and range of the expansion valve can be judged by the high and low values of the evaporation pressure. The evaporation pressure is higher than the set value, indicating that the flow rate of the expansion valve is too large, which should be adjusted appropriately (the adjustment rod needs to be rotated in a clockwise direction); the evaporation pressure is lower than the set value, indicating that the flow rate of the expansion valve is low , should be properly adjusted (that is, rotate the adjustment lever in a counterclockwise direction).

The expansion valve needs to be automatically adjusted within a specific range of operating conditions, and it also needs to be adjusted when the refrigeration system is being debugged. ...
... Once the expansion valve is functioning properly, it can be adjusted automatically.

When adjusting the expansion valve, a low-pressure pressure gauge can be installed on the suction pipe of the compressor, and the change of the suction pressure can be known through the change of the data on the pressure gauge.

If it is necessary to adjust the setting range of the expansion valve, it can be roughly divided into two steps. The coarse adjustment is performed when the operation starts, and the fine adjustment is required when the working temperature of the refrigeration system is close to the set value.

In the process of adjusting the expansion valve, it should be noted that the compressor will exhibit different physical phenomena under different operating conditions and ambient temperatures. In the case of high temperature, medium temperature and low temperature, the evaporation pressure of the compressor shows different frosting on the suction pipe. During debugging, the opening degree of the expansion valve should be adjusted according to the load.

The opening degree of the expansion valve is different, and the state of the superheat degree of the refrigerant at the suction end of the evaporator and the compressor is different. In general, superheat = return air temperature - evaporation temperature, where superheat refers to temperature difference, not temperature.

When reading the superheat, you need to grasp the timing, requiring stable high load and low load, temperature or pressure before shutdown and defrosting.

However, there is a delay in the transmission of the temperature sensing package. After each adjustment, the system should be allowed to run for a period of time, and at the same time, it is necessary to observe the changes in the suction pressure so that the direction of the next adjustment can be determined.

In a word, the adjustment of the expansion valve of the air-cooled box-type chiller is a relatively meticulous work, which requires the operator to have enough patience to do the adjustment work well.

We are a professional chiller equipment manufacturer, supporting customized services, please visit https://www.lneya-online.com/ for more details.

More About the Author

Website: https://www.lneya-online.com/ Specialized in the production of chillers, low temperature chillers, refrigeration and heating systems, refrigeration circulators, refrigeration and heating circulators, automotive test chillers, semiconductor test chillers, gas temperature controllers and Industrial refrigerators and more.

Total Views: 71Word Count: 520See All articles From Author

Add Comment

Business Articles

1. Lucintel Forecasts The Global Agoraphobia Market To Reach $2 Billion By 2030
Author: Lucintel LLC

2. Lucintel Forecasts The Global Acute Care Hospital Bed And Stretcher Market To Reach $11 Billion By 2030
Author: Lucintel LLC

3. Lucintel Forecasts The Global Fibromuscular Dysplasia Treatment Market Is Expected To Grow With A Cagr Of 7.3% From 2024 To 2030
Author: Lucintel LLC

4. Elegant Glass Block Styles To Elevate Your Interior Decor
Author: ADVAN

5. Discover The Beauty Of Floating Stair Treads In Design
Author: ADVAN

6. Maximizing Bulk Sms Services Online
Author: Make My SMS

7. A Comparative Guide For Front-end Development: Angularjs Vs Reactjs
Author: Alena Mage

8. 7 Ways To Find New Donors: Tips For New Nonprofits
Author: Yash

9. Convenient And Reliable Taxi Service In Denver: Serving Thornton And Longmont
Author: Rebecca Jones

10. Sustainability Meets Tech - Eco-friendly Solutions In Modern Interior Design
Author: Alaikha

11. A Brief Guide To Stainless Steel Round Bars
Author: Neelkamal Alloys LLP

12. Digital Marketing And Freelancing: The Perfect Match For The Modern Workforce
Author: shahla

13. Upgrade Your Financial Infrastructure: The Key Role Of An Accounting Data Migration Agency
Author: admin

14. Union Tee Manufacturers In India
Author: Vivek Shah

15. How To Remove Black Magic From Your Home
Author: Shardanand Shastri

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: