Precision Ac Units – Peripheral Cooling System

Profile Picture
By Author: Climaveneta
Total Articles: 27
Comment this article
Facebook ShareTwitter ShareGoogle+ ShareTwitter Share

Generally Precision AC Units, sometimes also called peripheral cooling units, are kept around the room in the periphery which gives them the name peripheral cooling units. Peripheral cooling units are used for applications having less heat load or Low density heat load application ( load generally 3-5 Kw per rack).


PAC units are available with following cooling medium:

Chilled Water Based System
DX refrigerant system
Hybrid/Dual Fluid system


Chilled Water Based System

Chilled water PAC units run on water as the cooling medium inside the coil. These systems are generally used in large server rooms/DC’s & bigger halls having dedicated chillers catering them.

DX Refrigerant System

Dx system is a refrigerant based system running on refrigerant as a cooling medium used in smaller server/UPS rooms. They are the most economical solution for any kind of cooling requirement.

Hybrid or Dual Fluid System

This kind of system runs on both refrigerant as well as chilled water circuits based on the requirement. Basically, it is a kind of redundant/flexible ...
... system rolled into one.
The units come with bottom or top air delivery.


Bottom Discharge Units/System

In Bottom discharge, cold air is blown down from the unit the reason is cold air being denser settles down in the room. As it picks up the heat from the server it becomes light & moves up in the room. Hot air is then sucked by the PAC units located along the periphery.. This being a natural cycle (cold air in the bottom & hot air in the top of the room) consumes less power. False floor act as pressurized plenum and generally ensure uniform air distribution throughout the room. Grilles are provided on the false floor to distribute the cold air in the room. Once cold air passes through servers it becomes hot & the same is discharged in the rear side of the server. The portion where cold air opening is provided is called the cold aisle & the rear end where hot air is discharged is known as the hot aisle. From the hot aisle the hot air is sucked by the PAC units, it can be done directly or via a false ceiling.
Some Advantages of False Flooring System
Loads of individual racks can vary from each other, in case of peripheral cooling units it can vary from 2/3 kw per rack to 10 kw /rack. Air volume required for each rack varies due to this, so for varying the air volume we can go for floor grilles with different amounts of opening. False floor can also be used for running the cables.
TOP Discharge Units/System:
In Top discharge units cold air is blown upwards from the unit which is taken to the server area with the help of Plenum & Duct. Then the cold air is distributed in front of the server via diffusers . The hot air is again sucked back by the PAC. This system eliminates the usage of False floor, & it is best suited for small capacities of servers.

For more details visit us
https://in.climaveneta.com/Web/Contacts/India/?utm_source=google&utm_medium=cpc&utm_campaign=Precision%20AC%20Units

Total Views: 247Word Count: 495See All articles From Author

Add Comment

Business Articles

1. Lucintel Forecasts The Super App Market In Germany To Grow With A Cagr Of 25.5% From 2025 To 2031
Author: Lucintel LLC

2. What Benefits Do Expert Acoustic Consultants Bring To Buildings In Egypt?
Author: DSP Consultants

3. Lucintel Forecasts The Semiconductor Equipment Refurbishment Market In Saudi Arabia To Grow With A Cagr Of 9% From 2025 To 2031
Author: Lucintel LLC

4. The Future Of Lab Management: Predictive Analytics And Machine Learning
Author: OneCare Health

5. N55 Engine Replacement – Complete Guide To Costs, Process, And Best Options For Bmw Owners
Author: Michael Jones

6. Pool Jacuzzi In Hyderabad
Author: vijji

7. Lucintel Forecasts The Semiconductor Equipment Refurbishment Market In Japan To Grow With A Cagr Of 9% From 2025 To 2031
Author: Lucintel LLC

8. Explore 3 Days Mount Meru Climbing: 4-day Climbing Itineraries
Author: Almighty Kilimanjaro

9. Travel Suppliers
Author: Anusha Raj

10. Understanding Cold Work Steel Carbide Structure: How It Affects Wear Resistance
Author: Vihaan

11. Lucintel Forecasts The Remote Firing Systems Market In United States To Grow With A Cagr Of 3.2% From 2025 To 2031
Author: Lucintel LLC

12. Lucintel Forecasts The Remote Firing Systems Market In Malaysia To Grow With A Cagr Of 3.2% From 2025 To 2031
Author: Lucintel LLC

13. The Importance Of The Amazing Silicone Foam Insulation
Author: Dongguan Senma New Materials Technology Co., Ltd

14. Why Premium Matchmaking Services Have Higher Success Rates Than Online Platforms
Author: Vihaan

15. House Removal Company In London: Making Your Move Simple And Stress-free
Author: Remila

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: