Precision Ac Units – Peripheral Cooling System

Generally Precision AC Units, sometimes also called peripheral cooling units, are kept around the room in the periphery which gives them the name peripheral cooling units. Peripheral cooling units are used for applications having less heat load or Low density heat load application ( load generally 3-5 Kw per rack).
PAC units are available with following cooling medium:
Chilled Water Based System
DX refrigerant system
Hybrid/Dual Fluid system
Chilled Water Based System
Chilled water PAC units run on water as the cooling medium inside the coil. These systems are generally used in large server rooms/DC’s & bigger halls having dedicated chillers catering them.
DX Refrigerant System
Dx system is a refrigerant based system running on refrigerant as a cooling medium used in smaller server/UPS rooms. They are the most economical solution for any kind of cooling requirement.
Hybrid or Dual Fluid System
This kind of system runs on both refrigerant as well as chilled water circuits based on the requirement. Basically, it is a kind of redundant/flexible ...
... system rolled into one.
The units come with bottom or top air delivery.
Bottom Discharge Units/System
In Bottom discharge, cold air is blown down from the unit the reason is cold air being denser settles down in the room. As it picks up the heat from the server it becomes light & moves up in the room. Hot air is then sucked by the PAC units located along the periphery.. This being a natural cycle (cold air in the bottom & hot air in the top of the room) consumes less power. False floor act as pressurized plenum and generally ensure uniform air distribution throughout the room. Grilles are provided on the false floor to distribute the cold air in the room. Once cold air passes through servers it becomes hot & the same is discharged in the rear side of the server. The portion where cold air opening is provided is called the cold aisle & the rear end where hot air is discharged is known as the hot aisle. From the hot aisle the hot air is sucked by the PAC units, it can be done directly or via a false ceiling.
Some Advantages of False Flooring System
Loads of individual racks can vary from each other, in case of peripheral cooling units it can vary from 2/3 kw per rack to 10 kw /rack. Air volume required for each rack varies due to this, so for varying the air volume we can go for floor grilles with different amounts of opening. False floor can also be used for running the cables.
TOP Discharge Units/System:
In Top discharge units cold air is blown upwards from the unit which is taken to the server area with the help of Plenum & Duct. Then the cold air is distributed in front of the server via diffusers . The hot air is again sucked back by the PAC. This system eliminates the usage of False floor, & it is best suited for small capacities of servers.
For more details visit us
https://in.climaveneta.com/Web/Contacts/India/?utm_source=google&utm_medium=cpc&utm_campaign=Precision%20AC%20Units
Add Comment
Business Articles
1. Lucintel Forecasts The Global Floral Perfume Market To Grow With A Cagr Of 6.8% From 2024 To 2031Author: Lucintel LLC
2. Lucintel Forecasts The Global Flip Flop Market To Grow With A Cagr Of 3.9% From 2024 To 2031
Author: Lucintel LLC
3. Best Manual Toothbrush In Uae: A Complete Guide To Smarter Oral Care Choices
Author: Smile Cart
4. Boost Your Tour Travel And Adventure Company With Expert Web Design And Seo Digital Marketing Services In Spain
Author: Vikram kumar
5. Lucintel Forecasts The Global Eye Shadow Market To Grow With A Cagr Of 6.2% From 2024 To 2031
Author: Lucintel LLC
6. Lucintel Forecasts The Global Comic Book Market To Grow With A Cagr Of 6.6% From 2024 To 2031
Author: Lucintel LLC
7. How Optical Prototyping Services In Spain Support Product Development
Author: Fotonica Gileyva
8. How Complex Optical Design In Madrid Supports High-tech Industries
Author: Fotonica Gileyva
9. Lucintel Forecasts The Global Coffee Beauty Product Market To Grow With A Cagr Of 5.9% From 2024 To 2031
Author: Lucintel LLC
10. Plaster Sand (plastering Manufactured Sand) Vs River Sand
Author: DOCTORSAND
11. How To Select The Right Chemical Injection System Suppliers For Oil & Gas Operations
Author: Priyadharshini
12. Lucintel Forecasts The Global Cc Cream Market To Grow With A Cagr Of 7.1% From 2024 To 2031
Author: Lucintel LLC
13. Maximizing Brand Growth: Why Dubai Businesses Are Partnering With Specialized Social Media Agencies
Author: Al murooj solutions
14. Create Your Website Easily With Host Sonu: A Step-by-step Tutorial
Author: contentcaddy
15. Unlock Power: Host Sonu Vps 8 Vcpu 16 Gb Ram Plan Explained
Author: contentcaddy