ALL >> Automobiles >> View Article
Calibration Of Rosemount Transmitter

1. Zero Calibration
When adjusting the transmitter, please turn off the protection setting, which is usually the red switch in front of the meter and its status may be ON or OFF.
If it is ON, you will not be able to make the calibration adjustment.
Rosemount Differential Pressure Transmitter 1151DP, Type Supply:45 VDC MAX Output:4-20mA
Figure 1: Rosemount Transmitter 1151DP5E22M6Y1
Calibration Steps
First, ventilate the transmitter, and connect measuring circuit with the manual operator.
Then, operate on the manual operator as follows.
Calibration Steps
Finally, calibrate the transmitter through zero calibration according to the manual operator.
It is important that the zero calibration must be for the transmitter whose output is within 3% around zero.
2. DAC Calibration (Output Calibration)
The output calibration means to calibrate the signal output conversion from digital-to-analog (DAC).
Operate on the manual operator as follows.
DAC Calibration
And set the control loop as manual mode.
Before confirming, ...
... notice that if the positive and negative wiring is correct.
Finally, the output of the field device is set to 4mA, and the output of the transmitter is 4mA. Then record the actual value of the reference table, and input the value on the transmitter.
Check whether the output of the manual operator is consistent with the value of the reference table. If it is consistent, change the output to 20mA, and then repeat the operation until it's accurate. If not, you should continue to input the reference value and inspect whether it is consistent with the manual operator output.
Finally, set the control loop as automatic control.
Rosemount High Static Pressure Transmitter 1151HP Type Supply:45 VDC MAX Output:4-20mA
Figure 2: Rosemount Transmitter 1151HP7S22M4B1
3. ADC Calibration (Sensor Calibration)
The sensor calibration is to calibrate the analog-to-digital converter (ADC). The main work to be done is zero calibration and full calibration. Full calibration requires three times the accuracy of the transmitter. Operate on the manual operator as follows.
ADC Calibration
If the accuracy value of transmitter is 0.25mA, the lower limit output will be 0.06mA.
Related Info
Benefits of Rosemount Fieldbus Transmitter
Rosemount Transmitter Series 1151, 2088, 2051, 3051CA, 3051S
OKmarts.com Online Store | We provide leading brands of refrigeration compressors, servo motors, Air cylinder and more all over the world. More product's information please visit https://okmarts.com/
Add Comment
Automobiles Articles
1. Customise Your Motorcycle With These Unique IdeasAuthor: Levi Fysh
2. Problems With An Audi That Demand Repair
Author: Oliver Mertin
3. Keep A Better Driving Record By Enrolling In A Driving School
Author: Eleanor Thompson
4. Tips To Help You Gain Confidence On Your First Day At A Driving School
Author: Eleanor Thompson
5. The Ultimate Guide To Finding The Best Auto Shipping Quote Online
Author: Rohit kapoor
6. Diagnosing Electrical Issues In Backhoe Loader Parts | Step-by-step Guide
Author: Seetech Parts
7. Alpr Surveillance In Canada: What Drivers Should Know About Privacy & Plates
Author: Alicia Reno
8. Backhoe Loader Muffler And Exhaust System: Function, Maintenance, And Importance
Author: Seetech Parts
9. How To Identify Genuine Vs Fake Activa Tyres
Author: Digital Hashtag
10. E Rickshaw Suppliers In India
Author: ronakk auto
11. The Impact Of Technology On Performance Management
Author: TrackHr App
12. Key Differences Between Backhoe Loaders And Excavators
Author: TrackHr App
13. Why Investing In High-quality Earth Moving Equipment Saves Money In The Long Run ?
Author: Seetech Parts
14. Best Business Performance Management Solutions For Startups
Author: TrackHr App
15. Diagnosing Hydraulic Issues With Pressure Sensor Ii (100 Bar)
Author: Seetech Parts