1. Zero Calibration
When adjusting the transmitter, please turn off the protection setting, which is usually the red switch in front of the meter and its status may be ON or OFF.

If it is ON, you will not be able to make the calibration adjustment.

Rosemount Differential Pressure Transmitter 1151DP, Type Supply:45 VDC MAX Output:4-20mA
Figure 1: Rosemount Transmitter 1151DP5E22M6Y1

Calibration Steps
First, ventilate the transmitter, and connect measuring circuit with the manual operator.

Then, operate on the manual operator as follows.
Calibration Steps
Finally, calibrate the transmitter through zero calibration according to the manual operator.

It is important that the zero calibration must be for the transmitter whose output is within 3% around zero.

2. DAC Calibration (Output Calibration)
The output calibration means to calibrate the signal output conversion from digital-to-analog (DAC).
Operate on the manual operator as follows.

DAC Calibration
And set the control loop as manual mode.

Before confirming, ...
... notice that if the positive and negative wiring is correct.
Finally, the output of the field device is set to 4mA, and the output of the transmitter is 4mA. Then record the actual value of the reference table, and input the value on the transmitter.

Check whether the output of the manual operator is consistent with the value of the reference table. If it is consistent, change the output to 20mA, and then repeat the operation until it's accurate. If not, you should continue to input the reference value and inspect whether it is consistent with the manual operator output.
Finally, set the control loop as automatic control.

Rosemount High Static Pressure Transmitter 1151HP Type Supply:45 VDC MAX Output:4-20mA
Figure 2: Rosemount Transmitter 1151HP7S22M4B1

3. ADC Calibration (Sensor Calibration)
The sensor calibration is to calibrate the analog-to-digital converter (ADC). The main work to be done is zero calibration and full calibration. Full calibration requires three times the accuracy of the transmitter. Operate on the manual operator as follows.
ADC Calibration
If the accuracy value of transmitter is 0.25mA, the lower limit output will be 0.06mA.

Related Info
Benefits of Rosemount Fieldbus Transmitter
Rosemount Transmitter Series 1151, 2088, 2051, 3051CA, 3051S

More About the Author

OKmarts.com Online Store | We provide leading brands of refrigeration compressors, servo motors, Air cylinder and more all over the world. More product's information please visit https://okmarts.com/

Total Views: 448Word Count: 325See All articles From Author

Add Comment

Automobiles Articles

1. Understanding The Role Of Jcb Rpm Meter In Engine Performance
Author: Seetech Parts

2. Knowing The Kind Of Harley Parts Available And Why The Originals Are Crucial
Author: Levi Fysh

3. Reasons Your European Car Needs Maintenance- An Overview
Author: Oliver Mertin

4. Tips To Follow When You Drive On The Roads- An Overview
Author: Eleanor Thompson

5. Questions You Must Ask The Driving Instructor Before Getting Enrolled!
Author: Eleanor Thompson

6. Car Repair Mistakes That Could Be Damaging Your Vehicle
Author: Erika Rhein

7. Gopiban Logistics - Best Transport Company In Pune For Reliable Transportation Services
Author: Gopiban Logistics

8. Reliable Vehicle Repair In Auckland – Keeping Your Car Safe And Road-ready
Author: Botany Vehicle Service

9. Why Choose Genuine Jcb Excavator Valve Block – 332/y3028
Author: Seetech Parts

10. Top 5 Tips For Stress-free Car Shipping Across The Usa
Author: Ship Auto Now

11. How To Find Affordable Car Service In Hawthorn
Author: Olivia Robinson

12. How To Replace Tooth In Jcb Buckets Step By Step
Author: Seetech Parts

13. Experience The Ultimate Off-road Power – Landcruiser 100 Series Exhaust By Outback Exhausts
Author: seo globo

14. Top Travel Neck Pillow & Car Neck Cushion Guide
Author: Creckk

15. Understanding Axial Piston Variable Displacement Pump In Hydraulics
Author: Seetech Parts

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: