Here's the recent articles submitted by oleg chechel
Articles By oleg chechel
Make-up Air Ventilation Fan
By: oleg chechel
Industrial Blower PT Air Make-Up System has the following advantages over coventional make-up air units:
* Offers savings in initial investment and operating costs;
* Provides draft-free and uniform air distribution from along tube rather than blasting air from a single source outlet;
* Uses less energy due to lower horsepower for the same supplied air volume and because of friction loss of blowing air through a heat transfer system is completely eliminated;
* Easier and less costly to install, as PT Fan system is relatively light in weight ans the polyethylene tubing can be installed in a fraction of time normally required for conventional ventilation ducts;
* Eliminates coil freeze-up problems typical for AHU with heating hot water and steam heat exchangers;
* Reclaims overhead heat wasted in most buildings - through mixing of outside air with inside hot air;
* Very quiet, normally within 20 Fan Sones;
* Flexible in capacity, which is achieved by running only the required number of PT units based on the temperature inside the building;
* Provides a more comfortable eworking environment by maintaining gentle air flow and uniform temperature distribution.(read
entire article)
View : 492 Times
Category : General
Ventilation By Positive Pressure Fan
By: oleg chechel
The following criteria should be considered for effective use of Positive Ventilation:
- The cone of air must cover the intake opening. The fan must be placed the correct distance from the structure such as that the cone of air forms a seal around the opening.
- The size and location of the discharge is important. The discharge, if at all possible should be as high and far away from the intake as is practical. The discharge size should be between 3/4 to 1/2 times the intake. This may not always be possible as the fire may have already dictated discharge locations and sizes; but whenever there is a choice, the above criteria should be used.
- It is important to control the ait flow between the intake and discharge. Positive pressure ventilation can move air long distances if proper control is maintained by opening and closing doors, windows, etc. It is important that firefighters understand not to open the structure too much: ie breaking windows, etc.(read
entire article)
View : 450 Times
Category : Others
Heavy Duty Industrial Blowers
By: oleg chechel
Tough applications mean tough fans and blowers by Industrial Blower Co. - a world wide distributor of industrial process ans OEM fans and blowers, as well as fan / blower components; including high pressure blowers, high temperature fans, spark resistant and explosion proof ventilators, tubeaxial and vaneaxial high pressure ventilators. CB Blower Co. also does existing fans and blowers repairs, re-build, as well as dynamical wheels balancing.(read
entire article)
View : 464 Times
Category : General
Mix Flow Fans Ventilators
By: oleg chechel
A unique features of the MVA Mixed Flow Fans include:
- Universal Mounting System that allows the unit to be field rotated at the job site
- Compact design with standard slip-fit duct connections for ease of installation
- UL/CSA listing for electrical is available
- Continuously welded housing with a standard powder paint finish suitable for indoor or outdoor applications
- A complete three plane vibration test of all assembled fans prior to shipment(read
entire article)
View : 387 Times
Category : General
Ventilation With Large Blowers
By: oleg chechel
Ventilating fans include several types such as duct fans, roof and ceiling ventilators, wall mounted fans, pressure blowers, and freestanding units with different mounting options. For extreme conditions and plants, drum fans can be used to move even larger amounts of air. These types of fans come with wheels attached and can be rolled to the area that circulation is needed the most. Some manufacturers even sell just the fan heads for a more freedom and a reduced assembly and cost on the company.(read
entire article)
View : 382 Times
Category : Real Estate and Foreclosure
High Temperature Ventilator And Fan
By: oleg chechel
Blowers with ambient air cooling systems handling hot airstreams must have sufficient airflow and be kept in operation until airstream temperatures cool below 120 F to prevent damage to the fan unit. The Tubeaxial fan ambient air cooling system is only effective while fan is operating.(read
entire article)
View : 464 Times
Category : Service
High Temperature Axial Blower Fans
By: oleg chechel
The Industrial Blower Co. complete high temperature fans line now include:
- Operating up to 2200 F, centrifugal, axial and plug fan types;
- Pre-engineered and custom made fans for all types of applications with vaiety of impeller types and accessories;
- CB Blower engineers provide a professional advice and recommend a right fan for every application & oven / plenum design(read
entire article)
View : 469 Times
Category : General
Fiberglass Frp Blower Ventialtors
By: oleg chechel
Hydrogen Sulfide builds up (H2S) in sewage plant facilities and causes an odor problem that has to be treated. Depending on the size of these stations corrosion resistant fans are needed. This gas can also be very volatile and will require explosion proof motor and static grounding of the fan housing by graphite impregnation that Canada Blower can provide too.(read
entire article)
View : 412 Times
Category : Business
Force Draft Ventilators And Blowers
By: oleg chechel
Industrial ventilation is the process of changing or replacing air in any space to control temperature or remove moisture, odors, smoke, heat, dust and airborne bacteria. Ventilation includes both the exchange of air to the outside as well as circulation of air within the building. It is one of the most important factors for maintaining acceptable indoor air quality in buildings. Methods for ventilating a building may be divided into mechanical/forced and natural types. Ventilation is used to remove unpleasant smells and excessive moisture, introduce outside air, and to keep interior building air circulating, to prevent stagnation of the interior air.(read
entire article)
View : 407 Times
Category : Business
Large Industrial Blower Fan
By: oleg chechel
Industrial centrifugal blowers come in a number of forms of which the most common is the squirrel cage blower. The common factor is the air is moving perpendicular to the axis of the part that is moving the air. Typically, the air is drawn in through the side of the unit, turns at low speed to encounter the inside of a spinning cylinder with ribs or vanes around the wall of the cylinder which fling the air out and away where it is captured and aimed through an outlet much smaller than the inlet.(read
entire article)
View : 485 Times
Category : Education