Forces that are not constant in amplitude or direction over time can cause solids to move repetitiously. We call this vibration. The similar motion imparted to the air is called sound. These phenomena are somewhat interchangeable since sound can cause vibration and vibration can cause sound. One difference is that sound is only dealt with when it is audible while vibration must be addressed even when it is outside the range of human perception. All fans must generate some vibration. They continuously rotate and, since nothing is perfect, cyclic forces must be generated. It’s only when vibration reaches a certain amplitude that we call it “bad.” Vibration may just be an indicator of some problem with a mechanism, or it may be a cause of other problems. High vibration can break down lubricants in the bearings and, in addition,
may cause metal fatigue in the bearings. Excessive vibration can cause fasteners to loosen or can cause fatigue failure of structurally loaded components. Finally, vibration can transmit into adjacent areas and interfere with precision processes, or create an annoyance for people.

There ...
... is a trend in the fan industry that is causing significant changes in fan design and in the manner in which fans are marketed. As a result of the maturing vibration measuring instrumentation market, computer software and maintenance training programs have been adapted which equate “low vibration” with long life, igher quality, and lower maintenance costs. The fan manufacturers used to be the “vibration experts” and set the tolerance for acceptable levels of vibration.

The forces which result in vibration in fans are primarily due to minor imperfections in the rotating components. The most common of these imperfections is that the center of mass does not coincide with the center of rotation. We call this “unbalance.” Unbalance is corrected by adding (or removing) weight so as to make the two centers coincide.

There are numerous other “imperfections” that can result in vibration. Some of the more common are as follows:

1) The center of V-belt sheave grooves is not concentric with center of rotation. This can be caused by a bent shaft, a bad bushing, or an improperly machined sheave. The end result is a tugging action between the two sheaves.
2) Misaligned sheaves will cause the belts to try to climb the sides of the sheaves, then slip back in the groove periodically, resulting in vibration.
3) Shafts that are not straight can cause an unbalance and also may force the bearings to rock or twist in an oscillatory manner.
4) Bearing flaws are a common source of vibration. Flaws on inner race, outer race, balls or rollers tend to generate vibration at predictable higher frequencies.
5) Setscrew mounted bearings can trap some misalignment between the bearing bore and the shaft. Sometimes this can be corrected by loosening one bearing, running the fan for a few seconds, then retorquing the setscrews. Repeat on the other bearing if required. Misalignment can also be trapped by having more than two bearings on a single shaft, and in this case it may be difficult to correct. The bearings can be aligned with the fan stationary, but the misalignment will reappear in operation.
6) Imperfect fan wheel shapes can cause non-uniform pressure generation and result in vibration.
7) Turbulent or eccentric airflow on the fan inlet (and sometimes the discharge) can excite vibrations.
8) Operating the fan at flows lower than where the peak pressure occurs can cause instabilities that result in vibration.
9) Rotating components that make contact with stationary parts (rubbing) can result in major noise and vibration.
10) Coupling misalignment tends to generate forces that commonly result in vibration in the axial direction.
11) The fan wheel impacting with solids or liquid in material conveying systems can shock load the fan into very high vibration.
12) Wind blowing on a roof mounted fan can excite large amplitude vibrations due to vortex shedding.

All fans are exposed to a variety of vibrational forces. Fortunately, most of the forces mentioned above are relatively small and cause no problems. However, as specified vibration levels are pushed lower and lower, more factors come into play. Each of these must be investigated before they can be excluded. A common characteristic of fans is that they tend to be large, bulky, and relatively light and flexible for their size compared to other rotating machinery. The impact of this is that small forces can result in large motions. Acceptance criteria are based on the magnitude of the motion, not on the force that creates the motion. Therefore, vibration energy must constitute a very small percentage of the total energy consumed by the fan.

The cumulative effect of many small sources of vibration is the creation of a background (lower limiting) vibration level. Once this background level is achieved, finer balancing is futile. In order to consistently achieve lower vibration levels than that typical to the fan many things may have to be done. The precision level of all fan components must be improved. The fan rigidity may need to be increased. The fan mounting arrangement must be very solid. Finally, air turbulence through the fan must be minimized.

If a fan is already built, and the specified levels cannot be achieved by balance, the fan vibration detective must go to work. All parts of the fan must be examined for precision, and any possible contributor to vibration energy must be considered and corrected if required. This is an expensive, time-consuming effort that can have severe negative consequences to a manufacturing shop’s production effort because of its unpredictability.

For additional information please refer to http://canadablower.com

Susan Terlitski
Industrial Process Engineer
canadablower@canadablower.com
Canada Blower
http://www.canadablower.com/hvac/index.html
http://www.canadablower.com/oem/index.html

Total Views: 446Word Count: 924See All articles From Author

Add Comment

General Articles

1. Rules For Safe Driving In United States
Author: Patrica Crewe

2. Barebone Vs. Prebuilt Vs. Custom Pc: Which Is Right For You?
Author: adlerconway

3. Best Seo Company In Uk That Delivers Real Growth
Author: doaguru infosystems

4. Global Nanomedicine Market Enters A High-growth Phase Driven By Precision Drug Delivery
Author: siddhesh

5. What Is The Future Of The Pet Equipment Market? Growth Forecasts & Insights
Author: siddhesh

6. Global Dental Biomaterial Market Outlook Accelerates With Restorative And Bioactive Innovations
Author: siddhesh

7. Spiritual Tripindi Shradha Pooja And Rahu Ketu Pooja In Trimbakeshwar
Author: Pandit Ramkrishna Guruji

8. How Air Filters Contribute To Better Sleep Quality
Author: Jack Hoover

9. Where To Buy Poppers In The Uk: Your Complete Guide To Stores Vs. Online Shopping
Author: ukpopper

10. How Law Firm Seo Services Help Attract High-value Clients
Author: Attorneyrankings

11. Custom Power Apps Solutions For Automating Complex Business Processes
Author: david

12. Tractors: The New Era of Comfort To Farmers While Cultivating!
Author: khetigaadi

13. Top Non Voice Projects Provider | Zoetic Bpo Services
Author: mohan

14. Simple Guide For Pitra Dosh Puja And Kaal Sarp Dosh Puja In Trimbakeshwar
Author: Pandit Anuj Guruji

15. How Technology Adoption Challenges Affect Long-term Business Strategy
Author: david

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: