Regenerative Blowers And Super High Pressure Fans

By Expert Author: Susanna Terlitskaia

One of the major benefits of a regenerative blower is its lack of maintenance and monitoring requirements. The impeller is the only moving part and is wear free and does not come in contact with the housing channels. Self-lubricated bearings are the only parts that wear.

Side Channel blowers are oilless and have no complicated intake/exhaust valving. Most can be mounted in any plane and, with dynamically balanced impellers, generate little vibration. Because they are nonpositive displacement compressor/vacuum pumps, they discharge air that is clean and pulsation free, which are important considerations for today's plant instruments and controls.

Regenerative blowers operate as a multistaged compressors. Each blade-to-blade regeneration stage results in a slight pressure increase. Total pressure rise from air entry to discharge yields a continuous operating pressure up to 300-in. w.g. (11 PSIg) or a vacuum to 14-in. Hg with continuous flows to more than 1400 scfm (Fig. 3).

Side Channel blowers are ideal for moving large volumes of air at low pressures or vacuums. Unlike positive displacement compressors and vacuum pumps, they pressurize air through a nonpositive displacement method. Typical regenerative blower applications include sewage aeration, vacuum lifting, vacuum packaging, pneumatic conveying, concrete aeration, pond aeration, vacuum tables, drying, dust/smoke removal, air sparging, and chip removal.

Of all air handling equipment, regenerative blowers are probably the least understood. However, when system parameters fall within their range, they can be among the most cost-effective methods for moving air and producing pressure or vacuum.

Regenerative blowers are sometimes called side channel blowers or ring compressors, terms that refer to their physical construction. They can be direct or belt driven. In direct drives, the impeller is mounted on an electric motor shaft. The number, size, and angle of the blades on the impeller determine pneumatic performance as well as the relationship between the impeller and housing. Some blowers have rather flat performance curves while others have steep ones.

The impeller spins within a housing with an inboard and outboard channel. It is from this configuration that the name side channel blower is drawn. As the impeller blades pass the inlet port, they draw air in. The impeller rotation pushes air outward and forward into the channels. The air then returns to the base of the blade. As the impeller spins, the process repeats. This regeneration gives the blower its pressure/vacuum capabilities.

Most blowers are single stage: air travels around the blower housing once and is discharged. Two-stage regenerative blowers can provide almost twice the pressure or vacuum of single-stage units. In a single-impeller, two-stage unit, air makes one revolution around the front side of the impeller. Then, instead of being discharged, the air is channeled to the backside of the impeller through internal porting. Air then makes another revolution around the backside of the impeller before it is discharged. Other two-stage configurations are also available, including designs that use two separate impellers in one housing or two impellers and housings.

The majority of blower failures are caused by improper installation or operation. Regenerative blowers have close internal clearances between the impeller and housing. It is important to prevent foreign material from entering that space. Ingested debris wedging between the impeller and housing can cause the blower to lock up and lead to a catastrophic failure. A blower should always be equipped with an intake filter. A 10-micron size is usually adequate. Filters must be kept clean. A blocked filter will starve flow.

Overpressurization can also cause deadheading (zero airflow through the blower) and catastrophic failure. Some blowers tolerate deadheading, but other models (typically those above 1 hp) must have air passing through them for cooling. If air does not pass through the blower, heat builds up in the impeller causing it to expand at a faster rate than the housing. Eventually the impeller locks up with the housing and the blower fails. A relief valve prevents overpressurization and deadheading conditions and allows air to pass through the blower.

For additional information please refer to http://www.americanblower.net

Susanna Terlitskaia
Industrial Ventilating Engineer
American Blowers Company
nis@primus.ca
http://www.americanblower.net/ForwardCurvedFans.html
http://www.americanblower.net/OEMFans.html

Total Views: 49Word Count: 659See All articles From Author

Technology, Gadget and Science Articles

1. Boost Your Business With Latest Trends In Ios App Development
Author: Harold Vance

2. Best Android Wear Watch Faces Apps For The First Half Of January 2017
Author: Tristan Smithson

3. Trusted Samsung Repair Centre In Birmingham – Samsungrepairing.uk
Author: Lucy

4. What Are The Different Types Of Plug Sockets?
Author: Nanshi Pacheco

5. Nasa’s Tryst With Vr
Author: Binda Shah

6. Purchase Hexagonal Boron Nitride To Use In Making Of Cosmetics
Author: Sukanya Pawar

7. Motorola Repair Centre In Uk - Motorolarepairing.uk
Author: Denzil

8. How To Fix Common Issues For Mobile Phone Repairs
Author: Angel Smith

9. Troubleshoot Cursor Issue In Nintendo Wii And Wii Controller Model
Author: Rose

10. Fascinating Reasons To Purchase Graphene
Author: Bhargav Himnshu

11. Buy Hidden Spy Camera In Delhi | Active India
Author: abdul salam

12. Sony Service Centre Uk
Author: Georgia Eliza

13. Motorola Droid Turbo Common Repair Issues
Author: Denzil

14. Digital Egt Gauges- Suitable For Most Exhaust Systems
Author: Joseph Polizzotto

15. Power Your Home For Less Money And Less Of A Carbon Foot Print
Author: Frank Breinling


Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: