Cast Aluminum Regenerative Blower

By Author: Oleg Tchechel
Total Articles: 25

The specifications to consider when selecting regenerative blowers include: maximum free air delivery, maximum pressure, and motor power. Free air delivery (FAD) is the actual air produced by the compressor pump at the rated pressure. Maximum FAD is usually rated at a pressure somewhat less than the maximum pressure available. Volume per unit time is the unit of measure. Maximum pressure is the maximum level of air pressure generated by the compressor. Typically, these units are referenced to one atmosphere, as in psig or psi gauge. Note that maximum flow may not occur at maximum pressure. Motor power is the rated power of motor or engine driving compressor pump.

Side channel blowers are relatively low-volume, high-pressure blowers that produce centrifugal airflow. They are used in compression blowers, vacuum blowers, and industrial blower applications. Compression regenerative blowers can be used or configured as a compressor or air supply unit. Vacuum regenerative blowers can be used or configured as a vacuum pump or exhauster for removal or suction of air, fumes, or gases. Selecting regenerative blowers requires an analysis of compressor or vacuum specifications, power sources, and features.

Vacuum specifications to consider when selecting regenerative blowers include: operating vacuum and pumping speed. Vacuum is often measured in torr, or mm Hg referenced above absolute zero pressure. Sometimes, the following reference terms are used: 1 torr and above, Rough Vacuum; 0.001 to 1.0 torr, Medium Vacuum; Below 0.001 torr, High Vacuum. There are other terms and standards used, such as medium vacuum and ultra-high vacuum; consult suppliers for application specifications. Pumping speed is the air volume capacity of vacuum pump. Typically, vacuum pumps are flow-rated according to the volume of air exhausted with no pressure differential across the pump.

There are four power source choices for regenerative blowers: DC power, AC single-phase, AC three-phase, and engine. Features for regenerative blowers include: control panels and pressure or vacuum gauges. Most control panels include adjustment controls instead of a simple, regulator knob. Regenerative blowers can also have a pressure or vacuum gauge or sensor with a dial or digital readout that monitors the pressure or vacuum levels in the system.

Industrial Pressure Blower Co. has introduced many high pressure blower systems to achieve static pressure, previously unachievable by single stage centrifugal blowers.

Series and parallel connected blower installations are often used to meet performance ranges beyond normal single stage blower capacities. For systems that require high ststic pressure, and especially high pressure TOGETHER with high temperature (where standard multi stage, positive displacement, screw, or regenerative type blowers can not be used) series of single stage centrifugal blowers can be used. Many times additional blower in the system can be advantageous. For instance, where two blowers are operating in series and one breaks down, the other may be able to "limp" the system along while the necessary maintenance is performed. Having on blower continue in operation can often allow limited production while the other is being repaired. Also, there are cases where having one blower continue in operation could prevent or at least minimize system or equipment damage from such things as high temperature ot contaminated airstreams.

Caution is necessary in selecting blowers for series installtion. It is generally accepted that most pre-engineered blowers are capable of withstanding twice their catalog rated static pressure. In other words, where two blowers are installed in series the second blower housing should withstand the higher pressure. There is, however, a need for concern when the combined pressure exceeds twice the rated static pressure for one blower. In series applications involving three or more blowers, or in any system in which positive or negative pressure exists prior to the consideration of the blowers, special housing reinforcement may be necessary.

Additional information can be found at the Industrial ACME Fan Company web site http://www.acmefan.net/index.html

Oleg Tchechel
Industrial Mechanical Process Engineer
ACME Fan Co.
nis@primus.ca
http://www.acmefan.net/profile.html
http://www.acmefan.net/product1.html

Total Views: 112Word Count: 637See All articles From Author

Environment Articles

1. How Solar Energy Works And How You Could Take Advantage From It?
Author: Solar Etribe

2. Battle Of The Solar Manufacturers
Author: Reek

3. An Intro To The Solar Hot Water Heater
Author: Ross Barkely

4. Say Hello To The Highly-efficient Solar On Grid Systems
Author: Solar on Grid Systems

5. Epa To Consider Controlling Polyfluoroalkyl Substances
Author: Environmental Resource Center

6. Solar Products Manufacturers In India
Author: Solar E tribe

7. The Future Of Solar Energy In The India What To Expect
Author: SOLAR eTRIBE

8. Solar Installation Training In India. How To Become One?
Author: SOLAR eTRIBE

9. Looking For Solar Leads? Find A Lead
Author: SolarEtribe

10. How To Choose The Right Solar Energy Leads
Author: Solar e tribe

11. How Can India Become Globally Competitive In Solar Module Manufacturing
Author: Reek

12. FundaciÓn Bioplanet - Lucha Por El Cambio ClimÁtico
Author: FUNDACIÓN BIOPLANET

13. Indoor Air Quality Maintenance – Important Factors To Know
Author: Mark Simon

14. Pest Control In Glasgow By Pest Control Expert Yaser Rashid
Author: Yaser Rashid

15. Radon Mitigation Ottawa – Improving Air Quality To Improve The Atmosphere
Author: Mark Simon

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: