Industrial Pressure Blower Co. distributes new style of Low Profile Positive Pressure Ventilators that have been designed to fit in tight compartments ans small spaces without scarificing performance or features. These compact ventilation blowers are available is both gasoline driven conviguration and with 115/230V single phase electric motor.

The Positive Pressure Blower is a high volume fan use to pressurize a burning structure, in case of fire, in order to force the smoke out. Positive Pressure Blowers are portable, gasoline powered fans, most of which utilize a 5.5 horsepower engine. The theory of positive pressure ventilation is based on the principal of even pressure distribution. Once a structure is pressurized, air and smoke can be forced out through any opening (similar to escaping from an inflated baloon).

Electric smoke ejectors (negative pressure ventilation) can be used for smoke removal but this has proven to be inferior to positive pressure ventilation.

What makes Positive Pressure Ventilation superior to negative pressure ?

* The risk of injury from the engaged structure is reduced ...
... while placing the fan in operation.
* Positive pressure ventilation is faster to set up and requires fewer personnel.
* The Positive Pressure Blower has a self contained power source, while electric fans require cords and adaptors.
* Smoke and heat is removed from all levels of the structure unlike negative pressure which can result in localized extraction.
* Quicker results. After initial knockdown, positive pressure ventilation can be initiated and will show immediate improvements in the interior conditions.
* It allows replacement of contaminants with vital cooler, cleaner air - especially in sealed or windowless buildings. It's also very effective in large and compartmentalized buildings, warehouses, schools, etc.
* Quick results allow firefighters faster entry due to lower heat levels and improved visibility.

The following criteria should be considered for effective use of Positive Ventilation:

- The cone of air must cover the intake opening. The fan must be placed the correct distance from the structure such as that the cone of air forms a seal around the opening.
- The size and location of the discharge is important. The discharge, if at all possible should be as high and far away from the intake as is practical. The discharge size should be between 3/4 to 1/2 times the intake. This may not always be possible as the fire may have already dictated discharge locations and sizes; but whenever there is a choice, the above criteria should be used.
- It is important to control the ait flow between the intake and discharge. Positive pressure ventilation can move air long distances if proper control is maintained by opening and closing doors, windows, etc. It is important that firefighters understand not to open the structure too much: ie breaking windows, etc.

The standard features of Industrial Pressure Blower Co. Positive Pressure Ventilators include: fold down "T" handle; 8" pneumatic tires with full width axle; a "tilt and lock" device that allows the unit to be angled 20 degrees up or down with infinite positions in between; sturdy and light 1 inch wrap around frame. Explosion proof electric motors are available as drivers too.

The optimum ventilator placement distance on most 6'6" doors is about five to six feet away. If placement is too close, the seal won't be achieved. If placement is too far away, the cone of air will be hitting well outside the opening.

Additional information can be found at the Industrial Pressure Blower Co. web site http://www.industrialpressureblower.com/blower.html.

Oleg Tchetchel
Canadian Industrial Air Systems Designer
Industrial Pressure Blower Co.
http://www.industrialpressureblower.com/fan.html
http://industrialpressureblower.com/inquiry.html

Total Views: 217Word Count: 573See All articles From Author

Add Comment

Business Articles

1. Lucintel Forecasts The Global Crude Heater Market Is Expected To Grow With A Cagr Of 4.5% From 2024 To 2030
Author: Lucintel LLC

2. How To Measure The Success Of Your Rpo Partnership
Author: VanatorRPO

3. Lucintel Forecasts The Global Cough Remedy Market To Reach $1 Billion By 2030
Author: Lucintel LLC

4. Are There Different Types Of Esd Tables Available?
Author: Jagadeesan

5. How To Extend The Lifespan Of Your Hydraulic Industrial Lift
Author: Jagadeesan

6. How Best Quality Skin Hydration Mask Work For Your Skin?
Author: Xtaz Mask

7. Mayank Domestic And International Movers | Call: @8792441400
Author: mayanksharma

8. Channel Partner Intelligence: The Power Of Collaborations To Unleash Growth
Author: Netscribes

9. How Customer Intelligence Helps Design Intelligent Business Practices
Author: Netscribes

10. The Importance And Evolution Of School Uniforms: A Comprehensive Guide
Author: abushaikh7261

11. Iso 17020 Certification Conformity Assessment - Comparison Of Iso 17020 And Iso 17025 Standards
Author: Sahin Alam

12. Dialyzer Market Size, Trends, Analysis, Demand, Outlook And Forecast By 2030
Author: pranju

13. How Can Ansoff Matrix Be Used For Developing Successful Business Strategies?
Author: Expandus Business Coaching

14. Deep Cleaning Service In Gurgaon
Author: Balaji Cleaning Agency

15. Lucintel Forecasts The Global Catheter Market To Reach $42 Billion By 2030
Author: Lucintel LLC

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: